Trägerchassis: Temperature variance
Titel: Trägerchassis
Rheological calculation
The results for temperature variance highlight areas in which the geometry of the part causes the surface temperature to be different from the average unit temperature at the end of the cycle. Red indicates areas that are warmer than average, whereas blue indicates areas that are colder than average. Red areas are possibly insufficiently cooled. It must be determined in these areas whether the cooling can be improved by additional cooling channels. This should be considered in conjunction with the cooling time variance result.